FAQs & Solutions
No Syrup:
| Is BIB or syrup box empty? | Replace the BIB. |
| Check BIB connectors. | Clean/re-install connector. |
| Check syrup regulator pressure. | Adjust the pressure. |
No Carbonated Water/Flat Drink:
| Is the carbonator plugged in? | Plug it back in. |
| Check CO2 pressure regulator. | Adjust the pressure |
| IS the CO2 cylinder empty? | Replace the cylinder when in gauge is in red |
| Check drink temperature. | Should be 40 F or less (without ice) |
Foaming Product:
| Is the drink too warm? | Should be 40 F or less (without ice) |
| Check water & syrup pressure. | Adjust the regulator. |
| Check the water & valves for dirt or syrup build up. | Clean nozzles in warm water. |
Drink too Warm:
| Is the ice bin full? | Tap down ice & fill. |
| Is the electric power supplied to dispenser? | Turn unit on and test outlet. |
| Is there anything obstructing the air flow at the electrical dispenser? | Remove any objects restricting air flow |
The Drink Does Not Taste Right:
| Identify if it is just one or all of them. | Check Ratio of water to syrup. |
| Is the correct BIB feeding the correct product? | Reconnect the BIB Connector. |
Syrup/CO2 Leaks:
| Are the liquid and gas sockets properly connected on the syrup tanks? | Reconnect Properly |
| Tighten or reconnect fittings at regulator or BIB connector. | If unable to stop leak locate the location of the leak & call Double J Beverage. |